Minimum cover requirements for nonprestressed cast in place concrete construction are given in table 20 6 1 3 1 of aci 318 14 building code requirements for structural concrete.
Minimum concrete wall reinforcement aci.
When the strain in the reinforcement is 0 005 or greater the section is tension controlled.
Concrete which is not cast against earth but exposed to earth or weather the concrete cover should be.
The tables use the terminology cases 1 and 2.
Values of tension ldand tension lap splice lengths in the tables are based on the provisions in aci 12 2 2.
Use on both faces.
The rcc member which is cast against the earth and exposed to earth the concrete cover should be not less than 3 inches.
The footing is an example of this kind.
Aci clear cover requirements.
The minimum ratio of required reinforcement is.
In final design corner regions will probably require a higher ratio of reinforcement due to moments from 2 way action.
Try 4 bars at 12 inches.
Thus a 5 bars which provide an area of 0 31 in2 would be needed.
So for a 12 inch thick by 12 inch wall or slab section the amount of steel needed to control shrinkage and temperature cracks is 0 0018 x 12 x 12 0 26 in2.
The reinforcement ratio in concrete beam design is th following fraction.
Reinforced concrete cantilever retaining wall analysis and design aci 318 14 reinforced concrete cantilever retaining walls consist of a relatively thin stem and a base slab.
All tabulated data are for grade 60 420 reinforcing bars in normalweight concrete with the concrete compressive strength f c ranging from 3000 to 8000 psi 21 to 56 mpa.
Reinforcing bars are placed in a concrete member with a minimum concrete cover to protect it from weather fire and other effects.
The temperature reinforcement shall not be less than inch at nine 9 inch center to center.
Reinforcement the minimum ratio of reinforcement area to gross concrete area is 0 0018.
F min 0 0015.
F min 0 002 for f y 40 000 psi s min 0 0018 for f y 60 000 psi for walls.
The stem may have constant thickness along the length or may be tapered based on economic and construction criteria.
The reinforcement ratio ρ must be less than a value determined with a concrete strain of 0 003 and tensile strain of 0 004 minimum.
Here i ll discuss the minimum concrete cover as specified in aci code.